ECG Accessories
- Fiab F9047 Disposable Electrode, 28x44 mm- Out of stock until June 2020As low as $8.03 $7.30
FIAB disposable pregelled electrodes for ECG, have features that make
them absolutely reliable during signal recording in rest tests. The model
F9047 is used also recording in stress test and for Holter monitoring.
They are compatible with different ECG devices on the market. After
opening, the pouch can be folded to ensure a better preservation of the
electrodes that remain inside. The products are Latex-free. - Fiab F9067 Disposable Electrode, 48x50 mm - Out of stock until June 2020As low as $9.41 $8.55
Disposable ECG electrode with liquid gel, Silver/Silver Chloride(SSC) sensor and stainless steel
snap. Disposable FIAB ECG electrodes are suitable both for rest and stress or Holter ECG recording,
with a direct application onto the skin. The SSC sensor permits a reliable and stable recording. The
external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air
and contaminating fluids. They compy with ANSI/AAMI EC12:2000 and permit the signal recovery
after defibrillator discharge. After opening, the pouch can be folded to ensure a better preservation of
the electrodes that remain inside.
The products are latex-free. - Fiab F9060P Disposable Electrode, Ø 40 mm - Out of stock until June 2020As low as $11.01 $10.01
Disposable ECG electrodes with solid gel, Silver/Silver Chloride(SSC) sensor and
stainless steel snap. Disposable FIAB ECG electrodes are suitable for rest, long term,
stress or Holter ECG recording, with a direct application onto the skin. The SSC
sensor permits a reliable and stable recording. The external layer in waterproof
medical grade PE foam protects the skin beneath the electrode from air and
contaminating fluids. They compy with ANSI/AAMI EC12:2000 and permit the signal
recovery after defibrillator discharge. After opening, the pouch can be folded to ensure
a better preservation of the electrodes that remain inside. The products are latex-free. - Fiab F2080P Disposable Electrode, Ø 40 mm - Out of stock until June 2020As low as $10.79 $9.81
Disposable ECG electrodes with solid gel, Silver/Silver Chloride (SSC) sensor and stainless
steel snap. The external surface is made of non woven fabric. The fabric is made of plastic
polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the
same time the resistance to liquids with which they may come into contact during their use.
Disposable FIAB ECG electrodes are suitable for rest, long term, stress or Holter ECG recording,
with a direct application onto the skin.
The SSC sensor permits a reliable and stable recording. They compy with ANSI/AAMI
EC12:2000 and permit the signal recovery after defibrillator discharge. After opening, the pouch
can be folded to ensure a better preservation of the electrodes that remain inside. The products
are latex-free. - Fiab F9079P/100 Disposable Electrode, 32x36 mm (oval) - Out of stock until June 2020As low as $18.82 $17.11
Disposable electrode, 32x36 mm (oval), SSC sensor, snap connection, FOAM support, paediatric.
- Fiab F9089P/100 Disposable Electrode, 32x36 mm (oval)As low as $17.94 $16.31
ECG electrodes with solid gel, Silver/Silver Chloride(SSC) sensor and stainless steel snap.
Disposable FIAB ECG electrodes are suitable both for rest and stress or Holter ECG
recording, with a direct application onto the skin. The SSC sensor permits a reliable and
stable recording. The external layer in waterproof medical grade PE foam protects the skin
beneath the electrode from air and contaminating fluids. They comply with ANSI/AAMI
EC12:2000 permitting the signal recovery after defibrillator discharge. After opening, the
pouch can be folded to ensure a better preservation of the electrodes that remain inside.
The products are latex-free. - Fiab PG10C Disposable Electrode, Ø 26 mm - Out of stock until June 2020As low as $7.16 $6.51
Disposable electrode, Ø 26 mm, SSC sensor, snap connection, FOAM support, paediatric and neonatal.
- Fiab F9069PRM Disposable Electrode, 32X36 mm (oval) - Out of stock until June 2020As low as $14.45 $13.14
Disposable ECG RADIOLUCENT electrodes with solid gel, Silver/Silver Chloride (SSC) sensor and carbon
snap. Disposable FIAB ECG electrodes are suitable for rest ECG recording, with a direct application onto
the skin. The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the
carbon snap that makes it radiolucent.
Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully
compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field.
The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems.
The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and
contaminating fluids. They compy with ANSI/AAMI EC12:2000 and permit the signal recovery after
defibrillator discharge. After opening, the pouch can be folded to ensure a better preservation of the
electrodes that remain inside.
The products are latex-free. - Fiab F9069NRM Disposable Electrode, Ø 26 mm- Out of stock until June 2020As low as $13.77 $12.52
Disposable ECG RADIOLUCENT electrodes with solid gel, Silver/Silver Chloride (SSC) sensor and carbon
snap. Disposable FIAB ECG electrodes are suitable for rest ECG recording, with a direct application onto
the skin. The SSC sensor permits a reliable and stable recording. The peculiar feature of the electrode is the
carbon snap that makes it radiolucent.
Neither of the components contains any ferromagnetic materials, therefore the electrodes are fully
compatible with MRI applications. The electrodes are MRI tested for use up to 3 T electro-magnetic field.
The use of the electrodes do not affect the safety and functioning of Magnetic Resonance Imaging Systems.
The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and
contaminating fluids. They compy with ANSI/AAMI EC12:2000 and permit the signal recovery after
defibrillator discharge. After opening, the pouch can be folded to ensure a better preservation of the
electrodes that remain inside.
The products are latex-free. -
-
- Limb Clamp -Adult (set 4) 13cm (l) x 6cm (w)$88.00 $80.00Limb Clamp -Adult (set 4) 13cm (l) x 6cm (w)
- Limb Clamp -Child (set 4) 9cm (l) x 4,5cm (w)$88.00 $80.00Limb Clamp -Child (set 4) 9cm (l) x 4,5cm (w)
-
-
-
-
-
-
-
-
-
-














































